Ethernet communicator E16

“Ethernet” communicator E16 directly connects to supported DSC, Paradox, UTC Interlogix (CADDX), Innerrange, Texecom, Honeywell, Crow and Pyronix alarm panels.

Communicator transmits full event information to the Central Monitoring Station.

Communicator also works with Protegus application. With Protegus users can control their alarm system remotely and get notifications about security system events. Protegus app is compatible with all security alarm panels from various manufacturers that are supported by the E16 communicator. Communicator can transmit event notifications to the Central Monitoring Station and work with Protegus simultaneously.

For panels from other manufacturers use the E16T communicator.

  • Direct control

  • Ethernet

  • Programmable contacts

  • Protocol: SIA

  • Protocol: TRK

  • RS485

  • Smart app

Description

Sends events to monitoring station receiver:

  • Sends events to TRIKDIS software or hardware receivers that work with any monitoring software.
  • Can send event messages to SIA DC-09 receivers.
  • Connection supervision by polling to IP receiver every 30 seconds (or by user-defined period).
  • The backup channel, that will be used if connection with the primary channel is lost.
  • With parallel communication channels events can be sent to two receivers at the same time.
  • When Protegus service is enabled, events are first delivered to CMS, and only then are sent to app users.

Works with Protegus app:

  • Push” and special sound notifications informing about events.
  • Remote system Arm/Disarm.

Remote control of connected devices (lights, gates, ventilation systems, heating, sprinklers, etc.).

  • Remote temperature monitoring (with iO or iO-WL expanders).
  • Different user rights for administrator and installer.

Notifies users:

  • Users can be notified about events with Protegus app.

Controllable outputs and inputs:

  • 3 double I/O terminals that can be set either as input (IN) or controllable output (OUT) terminals.
  • Outputs controlled by the Protegus app.
  • Add additional inputs and controllable outputs with wired and wireless iO expanders.

Quick setup:

  • Settings can be saved to file and quickly written to other communicators.
  • Two access levels for configuring the device for CMS administrator and for the installer.
  • Remote configuration and firmware updates.

Specifications

Parameter Description
Dual purpose terminals [IN/OUT] 3, can be set as either NC; NO; NC/EOL; NO/EOL; NC/DEOL; NO/DEOL (2,2 kΩ) type inputs or open collector (OC) type outputs with current up to 0,15 A, 30 VDC max.

Expandable with iO series expanders.

Power supply voltage 10-18 V DC
Current consumption 100 mA (on standby)

Up to 250 mA (while sending data)

Ethernet connection IEEE802.3, 10 Base-T, RJ45 socket
Transmission protocols TRK, DC-09_2007, DC-09_2012, TL150
Message encryption AES 128
Memory Up to 60 messages
Changing settings With TrikdisConfig computer program remotely or locally via USB Mini-B port
Operating environment Temperature from -10 °C to 50 °C, relative humidity – up to 80% at +20 °C
Communicator dimensions 88 x 62 x 26 mm
Weight 80 g

 

Compatible with

Brand Model
DSC® PC585, PC1404, PC1565, PC1616, PC1832, PC1864, PC5020
PARADOX® SPECTRA SP4000, SP5500, SP6000, SP7000, SP65, SP5500+, SP6000+, SP7000+
MAGELLAN MG5000, MG5050, MG5050E, MG5050+
DIGIPLEX EVO48, EVO192, EVOHD, NE96, EVO96
SPECTRA 1727, 1728, 1738
ESPRIT E55, 728ULT, 738ULT UTC
Interlogix® NetworX (Caddx) NX-4v2, NX-6v2, NX-8v2, NX-8e
Honeywell® Ademco Vista-15, Ademco Vista-20, Ademco Vista-48
Texecom® Premier 24, 48, 88, 168
Premier Elite 12, 24, 48, 64, 88, 168
Crow® Runner 4/8, Runner 8/16
Innerrange® Inception
Pyronix® MATRIX 424, MATRIX 832, MATRIX 832+, MATRIX 6, MATRIX 816

*Red – remote Arm/Disarm via Serial bus
** Communicator is compatible with other manufacturer control
panels when connected with GSM communicators G16T

Downloads

Manuals

IconE16 User Manual


March 20, 2024 | 3.48 MB

    Marketing

    IconE16 Brochure


    March 20, 2024 | 1 MB

    IconTrikdis communicator comparison


    March 21, 2024 | 1.48 MB

    IconTrikdis Products catalogue


    March 20, 2024 | 20.54 MB

      Certificates

      IconDeclaration of Conformity (E16, E16T)


      December 6, 2023 | 640.48 KB

        Software and firmware

        IconTrikdisConfig Full

        Latest
        April 21, 2023 | 66.42 MB

          3 reviews for Ethernet communicator E16

          1. Spyros Kintzonides

            excellent communicator and app! can do everything you need

          2. Pantelis Ch

            Is it compatible with Texecom 816 ?

          3. Csaba Hegedus

            When will this be compatible with Paradox Evo HD+

          Add a review

          Your email address will not be published. Required fields are marked *

          0
            0
            Quote Cart
            Your cart is empty

            Support ticket

            Support contacts
            Links